Caltech     IPAC           JPL           NASA

KI V2 Data Products

Calibrated V2 Output Description

Calibrated wide-band V2 data files are text files that areproduced by the ISC V2 calibration applicationwbCalib. The following gives an example of the output of wbCalib in default mode:

# option Kband

# 1 command line arguments processed

# >> Calibrating star HDC102713 at 11 49 41.715 +34 55 54.329

# >> with respect to 1 calibrators:

# >> star HDC101501 at 11 41 03.017 +34 12 05.888 size 0.9 error 0.06 1.9 degrees away from target

# Wideband calibration code settings for this run:

# > Calibrating only K-band (rejecting others at read)

# > Calibrating all frame rates

# > Calibrating incoherent spectrometer V2 data

# > Applying jitter correction

# > Using calibration scans within +/- 1 hr of the target scan

# > Weighting calibration scans WRT temporal proximity, variance doubles in 1 hr

# > Weighting calibration scans WRT sky proximity, variance doubles in 15 deg

# > No minimum calibrated scan uncertainty

# > Flagging calibration warnings when multiple calibrators disagree by more than 2 sigma

# > Rejecting the scan when multiple calibrators disagree by more than 3 sigma

# 246 data lines read from /home/bode/pti/data/100/100074.sum

# 295 data lines read from /home/bode/pti/data/100/100075.sum

# 356 data lines read from /home/bode/pti/data/100/100076.sum...

# Calibration data format:

# name #VisPts MJD m/d/y/h:m:s UT Delay(m) WL(um) \> CalVis Err RawVis Err SysVis Err #Cal \> U(m) V(m) HA(hr) FrameRate BLName

# Target HDC102713:

HDC102713 5 51618.30862 01/01/2000/7:24:24 7.40684 -18.4294 2.2078 0.628617 0.0181397 0.550502 0.0105877 0.875735 0.0188394 1 -46.877792 -99.115972 -0.66552 50 PTI_NS

HDC102713 5 51618.32589 01/01/2000/7:49:16 7.82132 -14.5302 2.2072 0.533166 0.0158086 0.46699 0.00989155 0.87588 0.0181731 1 -40.930193 -101.853953 -0.249901 50 PTI_NS

HDC102713 5 51618.35305 01/01/2000/8:28:23 8.47326 -9.49788 2.2044 0.435681 0.0118706 0.377309 0.00526829 0.866021 0.0202618 1 -30.624757 -105.368530 0.403829 50 PTI_NS

# 161 calibrated scans output under name HDC102713

# 161 total calibrated scans output on target HDC102713

The first section of the file is an extended preamble (with commentlines indicated by # symbols) containing the following pieces:

The second section of the file containes a list of calibrated outputdata. For each specified target/pseudonym there is a designationheader, and then a sequence of space delimited data lines. Thecontents of these data lines is described by the following table:

field#

content

comments

1

Target Designation

Target Designation (string)

2

# SUM Records

# of sum records averaged into this target scan (integer)

3

MJD

Modified Julian Date (day) (float)

4

UTC Date/Time

UTC Date/time in dd/mm/yyyy/hh:mm:ss format (string)

5

UTC

UTC Time (decimal hours) (float)

6

Delay

Average delay (m) (float)

7

Wavelength

SNR-weighted mean wavelength for scan (microns) (float)

8

CalVis

Calibrated wide-band visibility (dimensionless)

9

ErrVis

Std Error in calibrated visibility (dimensionless)

10

RawVis

Raw (L-1) wide-band visibility (dimensionless)

11

ErrRawVis

Std error in raw wide-band visibility (dimensionless)

12

SysVis

Estimated system visibility (dimensionless)

13

ErrSysVis

Std Error in estimated system visibility (dimensionless)

14

# Cals

Number of calibrators used in calibrating this scan (integer)

15

uCoord

u * lambda -- RA baseline projection (m) (float)

16

vCoord

v * lambda -- Dec baseline projection (m) (float)

17

HRangle

Hour angle on target for this scan (decimal hours) (float)

18

Frame Rate

Frame rate for this scan (Hz) (integer)

19

Baseline

Baseline designation for this scan (e.g. KI_K1K2) (string)

More detailed information is available in the documentation for wbCalib